Maintenance and troubleshooting of coaxial valves

Aug 24,2023


Fluid Control Coaxial Valve Series

Nominal Diameter: DN10-DN80

Medium Pressure: 0-200 bar

Actuation Type: Manual, Electric, Pneumatic

Connection Type: Threaded/Flanged

Sealing Material: HPU/NBR/FKM

 

Maintenance and Repair of Coaxial Valves

1) Regularly check the pipeline for rust, welding slag, dirt, and dust.

2) Ensure the power supply is functioning properly.

3) Perform regular maintenance.

4) When not in use and left for extended periods, store in a packaging box.

5) If the valve fails to meet operational requirements during use, or for regular inspection to prevent accidents after a long period of operation, remove the valve from the pipeline, clean it, and reinstall it after re-inspection.

 

Troubleshooting and Analysis:

Common Fault Conditions Causes of Failure Troubleshooting Methods
Solenoid Valve Inoperative No power input Connect the power supply
Broken wire or loose connection Replace the wire or correctly reconnect the wire
Incorrect or low power voltage Check the voltage with an instrument
Coil burnout Replace the coil
Ambient temperature too high, exceeding the valve's operating temperature Lower the ambient temperature or implement insulation measures
Valve core creep or inoperative Blockage or coking caused by mud or viscous media inside the valve Disassemble the valve, inspect, and clean
Pilot valve flow restrictor completely closed or too small opening Increase the flow restrictor opening appropriately
Main valve cannot close, causing leakage Rubber sealing ring aging and wear Replace
Damaged sealing gasket Replace
Damaged valve stem, causing the sealing surface to not close tightly Replace