Diagnosis and maintenance of air fluid supercharged pump


Problem Description:


Administrator reply:
Diagnosis and maintenance:
1. When the pressure pump suddenly stops working, check the control voltage signal first. If the signal is normal, turn off the gas source to ensure that there is no compressed air in the pump, the limited valve nut on the right end cover is opened, and the limit position is taken out. Valve stems, check whether the sealing ring leaves the groove. If you leave, push it back to the groove, reinstall the nut, and connect the gas source; if the pump is still not moved, then turn off the gas source to ensure that there is no compression in the pump compression. When air, replace the electromagnetic direction valve and connect the gas source; if the booster pump is still not working, please contact us or the nearby agent or supplier.
2. When the output pressure of the pressure pump decreases or does not reach the set pressure, please check whether there is a leakage of the pipeline. If there is no leakage, please check whether the pressure of the gas source is normal. If everything is normal, consider replacing the sealing parts.